Description
The new Explorer EXR series offers an intuitive interface, outstanding weighing performance, and an environmentally friendly design. The new generation Explorer establishes a groundbreaking standard for laboratory operations.
Features:
- Achieve consistant results with built-in automatic calibration, touchless sensors and a ventilated weighing pan. Get reliable data with the digital weighing cell and internal environment sensors.
- A intuitive 7-inch glass touchscreen, digital leveling, and simplified data management is easy to use. With an effortless installation and chemical-protective design it ensures efficiency and comfort.
- Supports HID connection to PC or keyboard without drivers, and provides 2-way communication with RS232, USB, Ethernet, Bluetooth, and WiFi for seamless data transfer.
Specifications
| Applications | 11 application modes: Basic Weighing, Parts Counting, Check Counting, Percent Weighing, Check Weighing, Dynamic Weighing, Totalization, Formulation, Differential, Density Determination, Peak Hold |
|---|---|
| battery-life | Not Applicable |
| capacity-g | 220 |
| Communication | USB Host (Type A) x 2, USB Device (Type C) x 1 Ethernet (RJ45) x 1, RS232 x 1; Optional Wi-Fi/ Bluetooth Dongle |
| dimensions | 14.2 x 9.1 x 15.5 in. |
| display | The 7-inch touch screen display |
| in-use-cover | Included |
| internal-calibration | AutoCal™ - Automatic |
| Legal-for-Trade | No |
| linearity | 0.06 mg |
| list-price | 9684.00 |
| Manual | Explorer_Balances_Manual.pdf |
| manufacturer-part-number | EXR225D |
| Minimum-Weight | 2 g 20 g (Typical) 8.2 g (Optimal) |
| model | EXPLORER |
| net-weight | 16.3 lb |
| pan-construction | Zinc Alloy |
| pan-size | Aero Pan 80 x 80 mm |
| power | AC Adapter Input: 100-240 VAC 0.5A 50-60 Hz AC Adapter Output: 12 VDC 1.5A 18W |
| readability-g | 0.00001 |
| repeatability | 0.01 mg (≤5% of Full Load), 0.01 mg (5% of Full Load) |
| Spec Sheet | Spec-Sheet_Explorer_Semi-Micro_Balance.pdf |
| stabilization-time | 0.1 mg: ≤2 seconds, 0.01 mg: ≤ 5 seconds |
| tare-range | To capacity by subtraction |
| Weighing-Units | 18 weighing units: g, mg, ct, N, oz, ozt, GN, dwt, mo, msg, tl H, tl S, tl T, tcl, tola, baht, Customer 1, Customer 2 |
| working-environment | Indoor use only. Altitude: 2000 m Working ambient temperatures: 5.0 °C – 40.0 °C Humidity: Maximum relative humidity 80% for temperatures up to 31 °C decreasing linearly to 50% relative humidity at 40°C. Mains supply voltage fluctuations: up to ±10% of the nominal voltage. Installation category II |